The market for complete sets of variable frequency water supply equipment is entering a "golden development period"
2025/11/10??????view:
The market for complete sets of variable frequency water supply equipment in China is entering a "golden development period". According to relevant data, during the 12th Five Year Plan period, the important development areas of China's petrochemical industry are the Yangtze River Delta, Pearl River Delta, and Bohai Rim region. By 2020, China's annual demand for petroleum will reach between 560 million tons and 600 million tons. Driven by the huge demand for oil, the central and eastern regions and coastal areas of China have become a rapidly developing regional market for the complete set of variable frequency water supply equipment industry.
In recent years, with the favorable investment environment and continuous deepening of infrastructure policies in China, the complete set of variable frequency water supply equipment industry will attract new opportunities for sustained growth. China's general machinery industry has made significant progress, especially in the continuous improvement of the technical level of products such as complete sets of variable frequency water supply equipment, which can provide some intermediate products for the market. In the next few years, the demand for complete sets of variable frequency water supply equipment in the domestic market will continue to grow by more than 10% and show an increasing trend year by year. Domestic enterprises producing complete sets of variable frequency water supply equipment have identified the development space of import substitution and have been researching and developing products in recent years, continuously making progress.
China is a major manufacturer of complete sets of variable frequency water supply equipment, and its astonishing annual output and export volume continue to expand and strengthen the domestic manufacturing team of complete sets of variable frequency water supply equipment. With an increasing number of products flooding the market, industry competition is becoming more intense.
Establish a new mechanism to encourage enterprises to innovate independently. According to the comprehensive planning and regional layout of the manufacturing industry for complete sets of variable frequency water supply equipment, a number of regional leading technology and product development laboratories, testing bases, and product development centers will be established. Establish technology diffusion stations relying on science and education institutions with strong innovation capabilities. Encourage and support the establishment of a complete set of variable frequency water supply equipment manufacturing technology research and development center.
Only by continuously strengthening and optimizing their own products, enhancing their sense of crisis, strengthening their corporate culture and market service concept, and achieving stability in stability, precision, and precision, can enterprises survive and develop in the increasingly competitive industry of complete variable frequency water supply equipment.
1、 Overview of complete frequency conversion water supply equipment products
To solve the negative pressure problem caused by the direct connection of water pumps to the tap water network in traditional water supply systems, our company has innovatively developed a new generation of Zhongying series non negative pressure variable frequency water supply equipment (pipe network regulation and boosting equipment). This product not only solves the problem of secondary pollution in underground water tanks, but can also be matched with purified water equipment and directly used as a booster device for drinking water. It can be used in any water supply system that requires pipeline boosting. This series of products has obtained multiple utility model patents.
The complete set of variable frequency water supply equipment is a new type of pressurized water supply equipment that has emerged in recent years. It achieves constant pressure water supply through microcomputer controlled variable frequency speed regulation. Firstly, set the working pressure of the water point according to the actual situation, and constantly monitor the pressure of the municipal pipeline network. When the pressure is lower than the user's required pressure, the microcomputer automatically controls the sub frequency converter to start, adjusts the speed of the water pump to increase until the pipeline pressure rises to the user's required pressure, and controls the water pump to operate at a constant speed for constant pressure water supply. When the water consumption increases, the speed increases, and when the water consumption decreases, the speed decreases, ensuring a constant water pressure for the user at all times.
The complete set of variable frequency water supply equipment is the sixth generation product upgraded by Zhongying Water Supply Company on the basis of variable voltage water supply equipment. This device adopts a fully enclosed design and can be directly connected to the municipal water supply network. It uses a variable frequency automatic control system to control the variable frequency pump through a vacuum controller and a steady flow regulating tank to protect the municipal network from negative pressure and automatically pressurize the user's pipeline network for variable frequency water supply. At the same time, it also saves a lot of investment in water supply facilities for users, and can supplement as much as the pressure is similar during use, greatly saving energy consumption. The water quality has no secondary pollution, and users can use hygienic domestic water. This device is currently a new type of secondary water supply equipment.
Selection Instructions for Complete Variable Frequency Water Supply Equipment
The complete set of variable frequency water supply equipment mainly consists of a variable frequency control cabinet, pressure sensors, water pumps, etc. The frequency conversion control cabinet consists of circuit breakers, frequency converters, contactors, intermediate relays, PLCs, etc.
1. Principles for selecting a complete set of variable frequency water supply equipment and water supply system
(1) The capacity of the reservoir should be greater than the hourly large water supply.
(2) The head of the water pump should be greater than the actual water supply height.
(3) The total flow rate of the water pump should be greater than the actual large water supply.
(4) Selection of frequency conversion control cabinet:
Users can determine the model and number of water pumps based on the water supply volume and height, and then select the appropriate control cabinet.
2. Complete set of variable frequency water supply equipment with variable frequency drive
According to the process requirements, it is recommended to use ABB ACS600 series frequency converters. The ACS 600 series frequency converter is a high-performance frequency converter developed by ABB using direct torque control (DTC) technology and advanced manufacturing processes. It has a wide power range, excellent speed and torque control characteristics, complete protection functions, flexible programming capabilities, high reliability, and small size.
Main technical data of the complete set of variable frequency water supply equipment:
Power range: 1.8-3000kW
Power supply voltage: 380/400/415/440/460/480/500VAC 3-phase ± 10%;
Power frequency: 35-50Hz
Control connection: 2 programmable analog inputs (AI); 1 programmable analog output (AO);
5 programmable digital inputs (DI); Two programmable digital outputs (DO).
Continuous load capacity: 150% In, 1 minute allowed every 10 minutes
Serial communication capability: The standard RS-485 interface allows the frequency converter to be easily connected to a computer.
Protection features: overcurrent protection I2t、 Overvoltage protection, undervoltage protection, overheating protection, short circuit protection, grounding protection, undervoltage buffering, motor undervoltage/overload protection, locked rotor protection, serial communication fault protection, AI signal loss protection, etc.
The complete set of variable frequency water supply equipment has a compact exterior structure and is easy to install. The product has undergone various electrical specification certifications and complies with GE, UL, and quality certification systems such as ISO9001 and ISO4001.
The direct torque control (DTC) function of the frequency converter in the complete set of variable frequency water supply equipment is currently the best motor control method. It can directly control the core variables of all AC motors in the Zhongying complete set of variable frequency water supply equipment without speed feedback, and can achieve control of motor speed and torque.
The complete set of variable frequency water supply equipment ACS600 frequency converter is equipped with eight application macros, including PID, PFC, and pre flux. Simply select the desired application macro, and all corresponding parameters will be automatically set. The input and output terminals will also be automatically configured. These preset application macro configurations greatly save debugging time and reduce errors.
3. Programmable controller for complete set of variable frequency water supply equipment
It is recommended to use Siemens S7-200 PLC. The SIMATIC S7-200 programmable controller is a modular small and medium-sized PLC system that can meet applications with moderate performance requirements; A wide range of functional modules can effectively meet and adapt to automatic control tasks, and various individual modules can be combined for expansion; The simple and practical decentralized structure and multi interface network capability make the application very flexible; Convenient for users and simple fanless design; When the control tasks increase, they can be freely expanded; The extensive integration of functions makes its functionality very powerful.
Multiple performance increasing CPUs and rich I/O expansion modules with many convenient functions allow users to choose the appropriate module according to their actual application. When the task scale expands, additional modules can be used at any time to expand the PLC.
Technical specifications of the complete set of variable frequency water supply equipment:
1. Water supply flow rate 0-1500 M3/H head
Control motor power 0.75-1500KW
3 households with water supply ranging from 10 to 10000 households
4. Pressure control range 0.15-1.6MPa
5. Average power saving rate of 30-60%
Complete set of variable frequency water supply equipment product usage:
Domestic and fire water supply for urban residential areas, high-rise buildings, hotels, and restaurants
Secondary booster pump station for tap water and clean liquid transportation pipeline system
◇ Heating, ventilation, air conditioning, boiler, bathroom and other cold and hot system water supply;
◇ Automatic water supply for square music fountains and waterfalls;
Fire protection, sprinkler, production, and domestic water supply for industrial and civil buildings;
Technical characteristics of complete frequency conversion water supply equipment:
The complete set of variable frequency water supply equipment should determine effective technical measures and reliable anti negative pressure control systems to prevent the impact on the hydraulic conditions of the municipal water supply network based on local and actual water usage conditions. The working status of the anti negative pressure control system should be clearly marked.
When a building has dual power and dual water source conditions, the complete set of variable frequency water supply equipment for the building should use power and water sources with the same conditions.
The complete set of variable frequency water supply equipment should use pipeline stacked variable frequency water supply equipment that meets the requirements of the health department.
Determination of design flow rate for complete frequency conversion water supply equipment:
1. The design flow rate of building water supply should meet the following requirements: when there is no high-level water tank, the design flow rate should be determined according to the design second flow rate;
When there is a high-level water tank, the design flow rate should be determined based on the hourly average flow rate per second.
3. The design flow rate of water supply in residential areas should meet the following requirements: when the water supply scale is less than 3000 people, the design flow rate should meet the following requirements:
1) When all buildings in the community are directly supplied with water through outdoor pipelines, the design flow rate should be determined based on the design second flow rate of the building's domestic water.
2) When all buildings in the community are supplied with high-level water tanks, the design flow rate should be determined based on the average hourly flow rate of the building's domestic water usage.
3) When the buildings in the community are supplied with both outdoor pipe networks and high-level water tanks, the flow rate should be calculated separately according to 1) and 2) of this article, and the larger value should be taken as the design booster water volume.
4) When the water supply scale exceeds 3000 people, the design flow rate should be determined based on the average hourly flow rate inside the building.
Installation requirements for complete frequency conversion water supply equipment:
1. Before installation, carefully check whether there are any hard objects inside the pump body to avoid damaging the impeller and pump body during operation.
2. During installation, pipeline management should not be added to the pump to prevent deformation and affect normal operation. 3. Tighten the anchor bolts to prevent vibration during start-up from affecting the performance of the pump.
4. Install regulating valves on the inlet and outlet pipelines of the pump, and install pressure gauges near the pump outlet to control the pump's operation within rated conditions and ensure its normal use.
5. If a check valve is installed in the discharge pipeline, it should be installed outside the gate valve.
6. The installation methods of pumps are divided into rigid connection installation and flexible connection installation.
Application scope of complete frequency conversion water supply equipment
Newly built residential communities, office buildings, hotels, and other domestic water sources.
Low level tap water pressure cannot meet the requirements for firefighting water.
Transforming the existing pneumatic water supply equipment can fully utilize the existing pneumatic tank.
For already built water tanks, a non negative pressure equipment can be used to share the water supply with the tank, further saving energy.
☆ Intermediate booster pump station for water supply in the water plant.
Production and domestic water use of industrial and mining enterprises.
In recent years, with the favorable investment environment and continuous deepening of infrastructure policies in China, the complete set of variable frequency water supply equipment industry will attract new opportunities for sustained growth. China's general machinery industry has made significant progress, especially in the continuous improvement of the technical level of products such as complete sets of variable frequency water supply equipment, which can provide some intermediate products for the market. In the next few years, the demand for complete sets of variable frequency water supply equipment in the domestic market will continue to grow by more than 10% and show an increasing trend year by year. Domestic enterprises producing complete sets of variable frequency water supply equipment have identified the development space of import substitution and have been researching and developing products in recent years, continuously making progress.
China is a major manufacturer of complete sets of variable frequency water supply equipment, and its astonishing annual output and export volume continue to expand and strengthen the domestic manufacturing team of complete sets of variable frequency water supply equipment. With an increasing number of products flooding the market, industry competition is becoming more intense.
Establish a new mechanism to encourage enterprises to innovate independently. According to the comprehensive planning and regional layout of the manufacturing industry for complete sets of variable frequency water supply equipment, a number of regional leading technology and product development laboratories, testing bases, and product development centers will be established. Establish technology diffusion stations relying on science and education institutions with strong innovation capabilities. Encourage and support the establishment of a complete set of variable frequency water supply equipment manufacturing technology research and development center.
Only by continuously strengthening and optimizing their own products, enhancing their sense of crisis, strengthening their corporate culture and market service concept, and achieving stability in stability, precision, and precision, can enterprises survive and develop in the increasingly competitive industry of complete variable frequency water supply equipment.
1、 Overview of complete frequency conversion water supply equipment products
To solve the negative pressure problem caused by the direct connection of water pumps to the tap water network in traditional water supply systems, our company has innovatively developed a new generation of Zhongying series non negative pressure variable frequency water supply equipment (pipe network regulation and boosting equipment). This product not only solves the problem of secondary pollution in underground water tanks, but can also be matched with purified water equipment and directly used as a booster device for drinking water. It can be used in any water supply system that requires pipeline boosting. This series of products has obtained multiple utility model patents.
The complete set of variable frequency water supply equipment is a new type of pressurized water supply equipment that has emerged in recent years. It achieves constant pressure water supply through microcomputer controlled variable frequency speed regulation. Firstly, set the working pressure of the water point according to the actual situation, and constantly monitor the pressure of the municipal pipeline network. When the pressure is lower than the user's required pressure, the microcomputer automatically controls the sub frequency converter to start, adjusts the speed of the water pump to increase until the pipeline pressure rises to the user's required pressure, and controls the water pump to operate at a constant speed for constant pressure water supply. When the water consumption increases, the speed increases, and when the water consumption decreases, the speed decreases, ensuring a constant water pressure for the user at all times.
The complete set of variable frequency water supply equipment is the sixth generation product upgraded by Zhongying Water Supply Company on the basis of variable voltage water supply equipment. This device adopts a fully enclosed design and can be directly connected to the municipal water supply network. It uses a variable frequency automatic control system to control the variable frequency pump through a vacuum controller and a steady flow regulating tank to protect the municipal network from negative pressure and automatically pressurize the user's pipeline network for variable frequency water supply. At the same time, it also saves a lot of investment in water supply facilities for users, and can supplement as much as the pressure is similar during use, greatly saving energy consumption. The water quality has no secondary pollution, and users can use hygienic domestic water. This device is currently a new type of secondary water supply equipment.
Selection Instructions for Complete Variable Frequency Water Supply Equipment
The complete set of variable frequency water supply equipment mainly consists of a variable frequency control cabinet, pressure sensors, water pumps, etc. The frequency conversion control cabinet consists of circuit breakers, frequency converters, contactors, intermediate relays, PLCs, etc.
1. Principles for selecting a complete set of variable frequency water supply equipment and water supply system
(1) The capacity of the reservoir should be greater than the hourly large water supply.
(2) The head of the water pump should be greater than the actual water supply height.
(3) The total flow rate of the water pump should be greater than the actual large water supply.
(4) Selection of frequency conversion control cabinet:
Users can determine the model and number of water pumps based on the water supply volume and height, and then select the appropriate control cabinet.
2. Complete set of variable frequency water supply equipment with variable frequency drive
According to the process requirements, it is recommended to use ABB ACS600 series frequency converters. The ACS 600 series frequency converter is a high-performance frequency converter developed by ABB using direct torque control (DTC) technology and advanced manufacturing processes. It has a wide power range, excellent speed and torque control characteristics, complete protection functions, flexible programming capabilities, high reliability, and small size.
Main technical data of the complete set of variable frequency water supply equipment:
Power range: 1.8-3000kW
Power supply voltage: 380/400/415/440/460/480/500VAC 3-phase ± 10%;
Power frequency: 35-50Hz
Control connection: 2 programmable analog inputs (AI); 1 programmable analog output (AO);
5 programmable digital inputs (DI); Two programmable digital outputs (DO).
Continuous load capacity: 150% In, 1 minute allowed every 10 minutes
Serial communication capability: The standard RS-485 interface allows the frequency converter to be easily connected to a computer.
Protection features: overcurrent protection I2t、 Overvoltage protection, undervoltage protection, overheating protection, short circuit protection, grounding protection, undervoltage buffering, motor undervoltage/overload protection, locked rotor protection, serial communication fault protection, AI signal loss protection, etc.
The complete set of variable frequency water supply equipment has a compact exterior structure and is easy to install. The product has undergone various electrical specification certifications and complies with GE, UL, and quality certification systems such as ISO9001 and ISO4001.
The direct torque control (DTC) function of the frequency converter in the complete set of variable frequency water supply equipment is currently the best motor control method. It can directly control the core variables of all AC motors in the Zhongying complete set of variable frequency water supply equipment without speed feedback, and can achieve control of motor speed and torque.
The complete set of variable frequency water supply equipment ACS600 frequency converter is equipped with eight application macros, including PID, PFC, and pre flux. Simply select the desired application macro, and all corresponding parameters will be automatically set. The input and output terminals will also be automatically configured. These preset application macro configurations greatly save debugging time and reduce errors.
3. Programmable controller for complete set of variable frequency water supply equipment
It is recommended to use Siemens S7-200 PLC. The SIMATIC S7-200 programmable controller is a modular small and medium-sized PLC system that can meet applications with moderate performance requirements; A wide range of functional modules can effectively meet and adapt to automatic control tasks, and various individual modules can be combined for expansion; The simple and practical decentralized structure and multi interface network capability make the application very flexible; Convenient for users and simple fanless design; When the control tasks increase, they can be freely expanded; The extensive integration of functions makes its functionality very powerful.
Multiple performance increasing CPUs and rich I/O expansion modules with many convenient functions allow users to choose the appropriate module according to their actual application. When the task scale expands, additional modules can be used at any time to expand the PLC.
Technical specifications of the complete set of variable frequency water supply equipment:
1. Water supply flow rate 0-1500 M3/H head
Control motor power 0.75-1500KW
3 households with water supply ranging from 10 to 10000 households
4. Pressure control range 0.15-1.6MPa
5. Average power saving rate of 30-60%
Complete set of variable frequency water supply equipment product usage:
Domestic and fire water supply for urban residential areas, high-rise buildings, hotels, and restaurants
Secondary booster pump station for tap water and clean liquid transportation pipeline system
◇ Heating, ventilation, air conditioning, boiler, bathroom and other cold and hot system water supply;
◇ Automatic water supply for square music fountains and waterfalls;
Fire protection, sprinkler, production, and domestic water supply for industrial and civil buildings;
Technical characteristics of complete frequency conversion water supply equipment:
The complete set of variable frequency water supply equipment should determine effective technical measures and reliable anti negative pressure control systems to prevent the impact on the hydraulic conditions of the municipal water supply network based on local and actual water usage conditions. The working status of the anti negative pressure control system should be clearly marked.
When a building has dual power and dual water source conditions, the complete set of variable frequency water supply equipment for the building should use power and water sources with the same conditions.
The complete set of variable frequency water supply equipment should use pipeline stacked variable frequency water supply equipment that meets the requirements of the health department.
Determination of design flow rate for complete frequency conversion water supply equipment:
1. The design flow rate of building water supply should meet the following requirements: when there is no high-level water tank, the design flow rate should be determined according to the design second flow rate;
When there is a high-level water tank, the design flow rate should be determined based on the hourly average flow rate per second.
3. The design flow rate of water supply in residential areas should meet the following requirements: when the water supply scale is less than 3000 people, the design flow rate should meet the following requirements:
1) When all buildings in the community are directly supplied with water through outdoor pipelines, the design flow rate should be determined based on the design second flow rate of the building's domestic water.
2) When all buildings in the community are supplied with high-level water tanks, the design flow rate should be determined based on the average hourly flow rate of the building's domestic water usage.
3) When the buildings in the community are supplied with both outdoor pipe networks and high-level water tanks, the flow rate should be calculated separately according to 1) and 2) of this article, and the larger value should be taken as the design booster water volume.
4) When the water supply scale exceeds 3000 people, the design flow rate should be determined based on the average hourly flow rate inside the building.
Installation requirements for complete frequency conversion water supply equipment:
1. Before installation, carefully check whether there are any hard objects inside the pump body to avoid damaging the impeller and pump body during operation.
2. During installation, pipeline management should not be added to the pump to prevent deformation and affect normal operation. 3. Tighten the anchor bolts to prevent vibration during start-up from affecting the performance of the pump.
4. Install regulating valves on the inlet and outlet pipelines of the pump, and install pressure gauges near the pump outlet to control the pump's operation within rated conditions and ensure its normal use.
5. If a check valve is installed in the discharge pipeline, it should be installed outside the gate valve.
6. The installation methods of pumps are divided into rigid connection installation and flexible connection installation.
Application scope of complete frequency conversion water supply equipment
Newly built residential communities, office buildings, hotels, and other domestic water sources.
Low level tap water pressure cannot meet the requirements for firefighting water.
Transforming the existing pneumatic water supply equipment can fully utilize the existing pneumatic tank.
For already built water tanks, a non negative pressure equipment can be used to share the water supply with the tank, further saving energy.
☆ Intermediate booster pump station for water supply in the water plant.
Production and domestic water use of industrial and mining enterprises.
Various circulating water systems.
- Pre:Integrated intelligent pumping 2025/11/10
- Next:The manufacturing industry of 2025/11/10


